A pressure transmitter converts the physical quantity 'pressure' into an industry-standard signal. In fact, it is a mechanical device that translates the expansive force of a liquid or gaseous sample into an electrical output.

Product details
Metrological parameters
Accuracy |
0.4% FS |
Hysteresis, repeatability |
0.05% FS |
Burst pressure |
150% FS |
Thermal compensation range |
0 - 70°C |
Thermal error |
0.2% / 10°C |
Long-term stability |
0.5% / year |
Material of wetted parts |
00H17N14M2 (SS316L) |
Material of casing |
0H18N9 (SS304) |
Electrical parameters
Output signal
|
4 - 20 mA, two-wire transmission 0 ÷ 10 V, three-wire transmission |
Power supply |
10…36 VDC – two-wire transmission 8…36 VDC – (spec. version) 13…30 VDC – three-wire transmission |
Load resistance (for current output) |
![]() |
Load resistance (for supply output) |
![]() |
Operating conditions
Operating temperature range (ambient temp) |
–25 - 80°C |
Medium temperature range |
25 - 120°C – direct measurement 25 - 170°C – measurement using an impulse line |